X-Cold BT (100-200-300-500 L)
The X-COLD BT line by Angelantoni Life Science represents the high-quality range of laboratory freezers that provide an ideal environment for storing biological samples and reagents.
The complete series includes freezers from 100 to 500 liters with glass or blind door execution, all with mechanical key locking and optionally equipped with opening through a personal ID card with RFID technology (BIOGUARD®).
The working temperature is -20°C.
The structure of the X-Cold BT line is fitted with 60 mm thick, high-density injected CFC-free polyurethane foam insulation.
The electronic board is of the latest generation, with a full color display, available in 2 versions, a 3-inch and a 7-inch touch screen, complete with a system for recording parameters.
All recorded data can be transferred to a computer via USB drive, or via WiFi/Ethernet/3G network technologies available through the use of special accessory modules.
It is also possible to transfer and store the same data on an ALS dedicated server via the CLOUD service provided.
- Glass or blind door
- Inside in stainless steel
- Mechanical lock with key
- Latest generation electronics
- USB port for data downloading
For further information please click on 'contact us' and fill in the form
- Bioguard® access control system
- Mounted on wheels with brake
- Safety thermostat to prevent freezing
- GSM module for alarm signaling
- WiFi, ETH and UMTS-3G modules for connection to the ALS Cloud
- Cryolog software for local monitoring
For further information please click on 'contact us' and fill in the form
The latest generation controller guarantees high performance and reliability thanks to:
- Simple and functional interface
- Password-protected access with 3 levels of privileges: USER, SERVICE and ADMINISTRATOR
- Three separate processors communicating with each other with CAN-BUS connection system
① Adjustment
② Alarm
③ System supervision/recording
The Alarm system ② has a dedicated PT100 probe, redundant with the one used for the Adjustment ①. Power is distributed to the two sections of ①Adjustment and ②Alarm which are physically separate (although mounted on the same support) and both have a dedicated power supply.
In case of the main power supply default, the alarm section ② continues to be powered by the back-up battery (with 36 hours autonomy) and provides power to the user panel ③ while maintaining the ability to display current data and store historical data.
The supervision unit ③ (user panel) constantly monitors and provides information on the correct operation of the alarm section ② and the control section ① and promptly notifies the user of any data storage anomalies.
Temperature | Available versions |
-20°C | 100 BT |
-20°C | 100 BT-GL |
-20°C | 200 BT |
-20°C | 200 BT-GL |
-20°C | 300 BT |
-20°C | 300 BT-GL |
-20°C | 500 BT |
-20°C | 500 BT-GL |